{"meta":{"status":200,"messages":[],"pagination":{"max":1,"offset":0,"count":1,"total":1,"pageNum":1,"totalPages":1,"sort":null,"currentUrl":"https://api.digitalmedia.hhs.gov/api/v2/resources/media.json?offset=0&max=1&ignoreHiddenMedia=1&format=json&id=5214&newUrlBase=http://www.cdc.gov/HICPAC/BSI","nextUrl":null,"previousUrl":null}},"results":[{"content":"
\nDownload the complete 2011 Guidelines for the Prevention of Intravascular Catheter-Related Infections [PDF - 1.05 MB]
\nThe terminology used to identify different types of catheters is confusing, because many clinicians and researchers use different aspects of the catheter for informal reference. A catheter can be designated by the type of vessel it occupies (e.g., peripheral venous, central venous, or arterial); its intended life span (e.g., temporary or short-term versus permanent or long-term); its site of insertion (e.g., subclavian, femoral, internal jugular, peripheral, and peripherally inserted central catheter [PICC]); its pathway from skin to vessel (e.g., tunneled versus nontunneled); its physical length (e.g., long versus short); or some special characteristic of the catheter (e.g., presence or absence of a cuff, impregnation with heparin, antibiotics or antiseptics, and the number of lumens). To accurately define a specific type of catheter, all of these aspects should be described (Table 1).
\nLikewise the terms used to describe intravascular catheter-related infections can also be confusing because catheter-related bloodstream infection (CRBSI) and central line\u2013associated bloodstream infection (CLABSI) are often used interchangeably even though the meanings differ.
\nCRBSI is a clinical definition, used when diagnosing and treating patients, that requires specific laboratory testing that more thoroughly identifies the catheter as the source of the BSI. It is not typically used for surveillance purposes. It is often problematic to precisely establish if a BSI is a CRBSI due to the clinical needs of the patient (the catheter is not always pulled), limited availability of microbiologic methods (many labs do not use quantitative blood cultures or differential time to positivity), and procedural compliance by direct care personnel (labeling must be accurate). Simpler definitions are often used for surveillance purposes. For example, CLABSI is a term used by CDC\u2019s National Healthcare Safety Network (NHSN) (visit NHSN CLABSI information) [206]. A CLABSI is a primary BSI in a patient that had a central line within the 48-hour period before the development of the BSI and is not bloodstream related to an infection at another site. However, since some BSIs are secondary to other sources other than the central line (e.g., pancreatitis, mucositis) that may not be easily recognized, the CLABSI surveillance definition may overestimate the true incidence of CRBSI.
\n \nNational estimates of CLABSI rates are available through CDC\u2019s NHSN, a surveillance system for healthcare-associated infections, and are available on CDC\u2019s website. A recent report highlights data from 1,545 hospitals in 48 States and the District of Columbia that monitor infections in one or more ICUs and/or non-ICUs (e.g., patient care areas, wards) [207]. Because BSI rates are influenced by patient-related factors, such as severity of illness and type of illness (e.g., third-degree burns versus post-cardiac surgery), by catheter-related factors, (such as the condition under which the catheter was placed and catheter type), and by institutional factors (e.g., bed-size, academic affiliation), these aggregate, risk-adjusted rates can be used as benchmarks against which hospitals can make intra-and inter-facility comparisons.
\nThe most commonly reported causative pathogens remain coagulase-negative staphylococci, Staphylococcus aureus, enterococci, and Candida spp [208]. Gram negative bacilli accounted for 19% and 21% of CLABSIs reported to CDC [209] and the Surveillance and Control of Pathogens of Epidemiological Importance (SCOPE) database, respectively [208].
\nFor all common pathogens causing CLABSIs, antimicrobial resistance is a problem, particularly in ICUs. Although methicillin-resistant Staphylococcus aureus (MRSA) now account for more than 50% of all Staphylococcus aureus isolates obtained in ICUs, the incidence of MRSA CLABSIs has decreased in recent years, perhaps as a result of prevention efforts [210]. For gram negative rods, antimicrobial resistance to third generation cephalosporins among Klebsiella pneumoniae and E. coli has increased significantly as has imipenem and ceftazidine resistance among Pseudomonas aeruginosa [209]. Candida spp. are increasingly noted to be fluconazole resistant.
\n \nThere are four recognized routes for contamination of catheters: 1) migration of skin organisms at the insertion site into the cutaneous catheter tract and along the surface of the catheter with colonization of the catheter tip; this is the most common route of infection for short-term catheters [37, 211, 212]; 2) direct contamination of the catheter or catheter hub by contact with hands or contaminated fluids or devices [213, 214]; 3) less commonly, catheters might become hematogenously seeded from another focus of infection [215]; and 4) rarely, infusate contamination might lead to CRBSI [216].
\nImportant pathogenic determinants of CRBSI are 1) the material of which the device is made; 2) the host factors consisting of protein adhesions, such as fibrin and fibronectin, that form a sheath around the catheter [217]; and 3) the intrinsic virulence factors of the infecting organism, including the extracellular polymeric substance (EPS) produced by the adherent organisms [218]. Some catheter materials also have surface irregularities that enhance the microbial adherence of certain species (e.g., S. epidermidis and C. albicans) [219, 220]. Catheters made of these materials are especially vulnerable to microbial colonization and subsequent infection. Due to the formation of the fibrin sheath, silastic catheters are associated with higher risk of catheter infections than polyurethane catheters [217]. On the other hand, biofilm formation by C. albicans occurs more readily on silicone elastomer catheter surfaces than polyurethane catheters [219]. Modification of the biomaterial surface properties has been shown to influence the ability of C. albicans to form biofilm [220]. Additionally, certain catheter materials are more thrombogenic than others, a characteristic that also might predispose to catheter colonization and infection [221, 222]. This association has led to emphasis on preventing catheter-related thrombus as an additional mechanism for reducing CRBSI [223, 224].
\nThe adherence properties of a given microorganism in relationship to host factors are also important in the pathogenesis of CRBSI. For example, S. aureus can adhere to host proteins (e.g., fibrinogen, fibronectin) commonly present on catheters by expressing clumping factors (ClfA and ClfB) that bind to the protein adhesins [217, 222, 225, 226]. Furthermore, adherence is enhanced through the production by microbial organisms, such as coagulase negative staphylococci [227, 228], S. aureus [229], Pseudomonas aeruginosa [230], and Candida species [231] of an extracellular polymeric substance (EPS) consisting mostly of an exopolysaccharide that forms a microbial biofilm layer [218, 232]. This biofilm matrix is enriched by divalent metallic cations, such as calcium, magnesium and iron, which make it a solid enclave in which microbial organisms can embed themselves [233\u2013235]. Such a biofilm potentiates the pathogenicity of various microbes by allowing them to withstand host defense mechanisms (e.g., acting as a barrier to engulfment and killing by polymorphonuclear leukocytes) or by making them less susceptible to antimicrobial agents (e.g., forming a matrix that binds antimicrobials before their contact with the organism cell wall or providing for a population of metabolically quiescent, antimicrobial tolerant \"persister\" cells) [228, 236, 237]. Some Candida spp., in the presence of dextrose-containing fluids, produce slime similar to that of their bacterial counterparts, potentially explaining the increased proportion of BSIs caused by fungal pathogens among patients receiving parenteral nutrition fluids [238].
\n \nWell-organized programs that enable healthcare providers to become educated and to provide, monitor, and evaluate care are critical to the success of this effort. Reports spanning the past four decades have consistently demonstrated that risk for infection declines following standardization of aseptic care [7, 12, 14, 15, 239\u2013241] and that insertion and maintenance of intravascular catheters by inexperienced staff might increase the risk for catheter colonization and CRBSI [15, 242]. Specialized \"IV teams\" have shown unequivocal effectiveness in reducing the incidence of CRBSI, associated complications, and costs [16\u201326]. Additionally, infection risk increases with nursing staff reductions below a critical level [30].
\n \nThe site at which a catheter is placed influences the subsequent risk for catheter-related infection and phlebitis. The influence of site on the risk for catheter infections is related in part to the risk for thrombophlebitis and density of local skin flora.
\nAs in adults, the use of peripheral venous catheters in pediatric patients might be complicated by phlebitis, infusion extravasation, and catheter infection [243]. Catheter location, infusion of parenteral nutritional fluids with continuous IV fat emulsions, and length of ICU stay before catheter insertion, have all increased pediatric patients\u2019 risk for phlebitis. However, contrary to the risk in adults, the risk for phlebitis in children has not increased with the duration of catheterization [243, 244].
\nThe density of skin flora at the catheter insertion site is a major risk factor for CRBSI. No single trial has satisfactorily compared infection rates for catheters placed in jugular, subclavian, and femoral veins. In retrospective observational studies, catheters inserted into an internal jugular vein have usually been associated with higher risk for colonization and/or CRBSI than those inserted into a subclavian [37\u201347]. Similar findings were noted in neonates in a single retrospective study [245]. Femoral catheters have been demonstrated to have high colonization rates compared with subclavian and internal jugular sites when used in adults and, in some studies, higher rates of CLABSIs [40, 45\u201347, 50, 51, 246]. Femoral catheters should also be avoided, when possible, because they are associated with a higher risk for deep venous thrombosis than are internal jugular or subclavian catheters [48\u201350, 53, 247]. One study [38] found that the risk of infection associated with catheters placed in the femoral vein is accentuated in obese patients. In contrast to adults, studies in pediatric patients have demonstrated that femoral catheters have a low incidence of mechanical complications and might have an equivalent infection rate to that of non-femoral catheters [248\u2013251]. Thus, in adult patients, a subclavian site is preferred for infection control purposes, although other factors (e.g., the potential for mechanical complications, risk for subclavian vein stenosis, and catheter-operator skill) should be considered when deciding where to place the catheter.
\nIn two meta-analyses, the use of real-time two-dimensional ultrasound for the placement of CVCs substantially decreased mechanical complications and reduced the number of attempts at required cannulation and failed attempts at cannulation compared with the standard landmark placement [60, 61]. Evidence favors the use of two-dimensional ultrasound guidance over Doppler ultrasound guidance [60]. Site selection should be guided by patient comfort, ability to secure the catheter, and maintenance of asepsis as well as patient-specific factors (e.g., preexisting catheters, anatomic deformity, and bleeding diathesis), relative risk of mechanical complications (e.g., bleeding and pneumothorax), the availability of bedside ultrasound, the experience of the person inserting the catheter, and the risk for infection.
\nCatheters should be inserted as great a distance as possible from open wounds. In one study, catheters inserted close to open burn wounds (i.e, 25 cm2 overlapped a wound) were 1.79 times more likely to be colonized and 5.12 times more likely to be associated with bacteremia than catheters inserted farther from the wounds [252].
\nType of Catheter Material. Polytetrafluoroethylene (Teflon \u00ae) or polyurethane catheters have been associated with fewer infectious complications than catheters made of polyvinyl chloride or polyethylene [36, 253, 254]. Steel needles used as an alternative to catheters for peripheral venous access have the same rate of infectious complications as do Teflon\u00ae catheters [33, 34]. However, the use of steel needles frequently is complicated by infiltration of intravenous (IV) fluids into the subcutaneous tissues, a potentially serious complication if the infused fluid is a vesicant [34].
\n \nHand hygiene before catheter insertion or maintenance, combined with proper aseptic technique during catheter manipulation, provides protection against infection [12]. Proper hand hygiene can be achieved through the use of either an al-cohol-based product [255] or with soap and water with adequate rinsing [77]. Appropriate aseptic technique does not necessarily require sterile gloves for insertion of peripheral catheters; a new pair of disposable nonsterile gloves can be used in conjunction with a \"no-touch\" technique for the insertion of peripheral venous catheters. Sterile gloves must be worn for placement of central catheters since a \"no-touch\" technique is not possible.